BELIZE · SOLCAYE HOUSE

Energy overview

Updated 10:45 AMNext scan at 11:00 AM

VEVOR LIVE FLOW

Solar is powering the home

SmartESS reports solar, AC output, battery power, and grid power. Battery level comes from the Bluetooth BMS when available.

Solar priority
Solar3.8 kWProducing
AC output1.2 kWInverter reported
Battery62%+2.6 kW charging
Grid0 WStandby

EMPORIA LIVE FLOW

Emporia meter flow is being monitored

Emporia independently measures grid power and inverter output. It cannot separate solar from battery power inside the inverter output.

Last Emporia scan —
Inverter0 WIdle
Home0 WEstimated load
Grid0 WStandby
↗
Solar generated14.6 kWh+18% vs. yesterday
⌂
Home consumption9.8 kWh8.0 kWh from solar
▰
Battery level62%Charging · 2.6 kW
↔
Grid imported1.8 kWhLast used at 6:30 AM

BATTERY LEVEL HISTORY

Battery levels over the last 7 days

Each point is a Bluetooth BMS reading collected by the Belize gateway. Gaps show periods without a reading.

7 days
205Ah battery— 100Ah battery—
205Ah active battery100Ah battery

TODAY

Energy history

4 kW2 kW0−2 kW
12 AM6 AM12 PM6 PM12 AM
SolarHomeBatteryGrid

ENERGY HISTORY

Understand every watt

Explore how energy moved between solar, home, battery, and grid.

Current Belize day—Solar generated
—Solar—Home—Battery—Grid
4 kW2 kW0−2 kW
Latest scanWaiting for synchronized readings.
12 AM6 AM12 PM6 PM12 AM

SOLAR OFFSET

81%

of home use covered by solar

Up 12 percentage points from the previous 7 days.

GRID DEPENDENCE

19%

of home use came from the grid

Most grid energy was used before sunrise.

BATTERY STORAGE

Two batteries, one clear history

The 205Ah battery is active. The disconnected 100Ah battery remains available for historical review.

Active

205Ah battery

Primary battery · JBD Bluetooth BMS

62%
↯
CURRENT STATECharging from solar
+2.6 kW
Voltage26.4 V
Current+98.5 A
Power+2.6 kW
Temperature28.1 °C
Remaining127.1 Ah
Charge cycles4
Disconnected

100Ah battery

Historical battery · last seen Oct 19

99%
—
CURRENT STATENot connected
Last state: Idle
Last voltage27.0 V
Last current0.0 A
Last power0 W
Temperature27.5 °C
Remaining98.8 Ah
Charge cycles37

BATTERY HEALTH

205Ah cell balance

All cells are within the expected balance range.

3.303.313.303.323.303.313.303.31

INVERTER

VEVOR configuration

Every setting reported by SmartESS, organized for review. This release is read-only.

Monitoring only
IN

VEVOR LVM3000-24L

Solar inverter

SmartESS cloud · last scan 10:45 AM

Operating stateInverter mode
PV input3.8 kW
AC output1.2 kW
Battery bus26.4 V
↯

POWER FLOW

Source priorities

Output source priority
Solar → Battery → Grid SBU
Charger source priority
Solar first
AC input voltage range
Appliance
Utility charging
Disabled
▰

BATTERY

Charging profile

Battery type
User-defined LiFePO₄
Bulk charging voltage
28.4 V
Float charging voltage
27.2 V
Low DC cut-off voltage
22.0 V
Back to grid voltage
23.0 V
Back to battery voltage
27.0 V
Maximum charging current
60 A
Maximum utility charge current
0 A
Battery equalization
Disabled
⌂

AC OUTPUT

Home supply

Rated output voltage
120 V
Output frequency
60 Hz
Power saving mode
Off
Overload bypass
Enabled
✓

PROTECTION

Device behavior

Restart after overload
Enabled
Restart after over-temperature
Enabled
Audible alarm
Enabled
LCD backlight
Enabled
Fault event recording
Enabled
ⓘ

Read-only protection is active

These are the exact values reported by the inverter. This application cannot write configuration changes.

SYSTEM HEALTH

Everything in one place

Every source has an explicit scan time and connection status.

GW

Belize gateway

Dell gateway · secure tunnel connected

10:45 AM5-minute scanOnline
EV

Emporia Vue 3

Grid and inverter-output metering

10:45 AM5-minute scanOnline
IN

VEVOR inverter

SmartESS cloud · monitoring only

10:45 AM5-minute scanOnline
B1

205Ah JBD BMS

Bluetooth · primary battery

10:45 AM5-minute scanOnline
B2

100Ah JBD BMS

Retained for historical reporting

Oct 19Last connectedDisconnected
ⓘ

Monitoring-only protection is active

The application cannot change inverter settings in this release.

ALERTS & NOTIFICATIONS

Only the signals that matter

In-app, Postmark email, and browser push. No SMS or WhatsApp.

!

Grid use detected before sunrise

The home imported 1.8 kWh between 4:45 AM and 6:30 AM.

Today · 6:30 AM
✓

Gateway connection restored

Buffered readings were synchronized successfully. No data was lost.

Oct 30 · 9:15 PM
i

100Ah battery marked disconnected

Historical readings remain available in the Batteries section.

Oct 19 · 4:00 PM

DELIVERY

Notification channels


Repeated alerts are grouped. Offline-source alerts wait for two missed scans before notification.